Plug-in backup power without the fuss
The APC Back-UPS 950VA is a 520W line-interactive UPS with automatic voltage regulation (AVR) and 4 Australian outlets, giving computers, routers and other electronics battery backup and surge protection.

AVR works with a 140 to 300V input window, and the unit transfers to battery in a typical 6 ms. Runtime is 1 minute at 480W full load and 6.5 minutes at 240W half load, and the lead-acid battery is replaceable.
Highlights
Key features
950VA/520W capacity
Line-interactive backup for PCs, modems and small office gear.
AVR
Input voltage limits of 140 to 300V.
Fast switchover
6 ms typical, 10 ms maximum transfer time.
Runtime
1 minute at 480W, 6.5 minutes at 240W.
Replaceable battery
Replacement battery RBC17.
The specs that matter
What these specs mean for you
Rated power: 950VA / 520W
VA and watts describe how much equipment the UPS can run. Add up the watts of everything you will plug in and leave some headroom.
UPS type: Line interactive
Line-interactive UPS units correct small voltage changes without using the battery. Online (double-conversion) units give the cleanest power for sensitive equipment.
Transfer time: 6 ms typical, 10 ms maximum
How quickly the UPS switches to battery when the power drops. A few milliseconds is fast enough for computers and network gear.
Replacement battery: RBC17
UPS batteries wear out over time. Knowing the replacement battery model makes it easy to keep the UPS working.
Ideal for
Home offices, small businesses and anyone protecting a PC, router or NAS from outages.
| Power | |
|---|---|
| Rated power | 950VA / 520W |
| UPS type | Line interactive |
| Wave type | Stepped approximation to a sinewave |
| Input voltage | 230V, limits 140–300V |
| Input power factor at full load | 0.54 |
| Transfer time | 6 ms typical, 10 ms maximum |
| Connectivity | |
| Outlets | 4 × Australian |
| Cable length | 1.22 m |
| Physical | |
| Form factor | Tower (not rack mountable) |
| Battery | Lead-acid |
| Acoustic level | 40dBA |
| Replacement battery | RBC17 |
| General | |
| Manufacturer part number | BX950MI-AZ |
| Warranty | 2-year APC warranty |
| In the box | |
| Contents | APC Back-UPS 950VA UPS (BX950MI-AZ) |
| Warranty | |
| Warranty | 2-year APC warranty |
Is it pure sine wave?
No. The output is a stepped approximation to a sinewave, so check your equipment's requirements.
How long will it run?
1 minute at 480W (full load) and 6.5 minutes at 240W (half load).
Can I replace the battery?
Yes. The listed replacement battery is RBC17.